Ürün adı: 3200 SERIES PEDIATRIC
Ürün kodu: 3200
Özellikleri:

The 3200 Series Pediatric Safe-T-Tubes™ feature an angled extraluminal limb to facilitate suctioning and airway management.  Shortened limbs can be ordered directly from our facility at no additional charge.  Available in sizes 6mm, 7mm, 8mm, and 9mm (outside diameter) in either clear or radiopaque medical grade silicone.  Each Safe-T-Tube™ set includes the tube, two plug/ring sets, and product information.  Additional plug/ring sets are available.  Refer to chart below for corresponding product codes.

INDICATIONS FOR USE:

Acute laryngotracheal injuries.
To support intrathoracic tracheal stenosis.
To support a reconstructed trachea.
Tracheal stenosis.
To support a reconstituted trachea.
Segmental resection and anastomosis.

SUPPLIED:

Sterile, 1 tube per carton

PRODUCT CODES:

320006     SIZE 6 mm, CLEAR
320007   SIZE 7 mm, CLEAR
320008   SIZE 8 mm, CLEAR
320009   SIZE 9 mm, CLEAR
     
32006R   SIZE 6 mm, RADIOPAQUE
32007R   SIZE 7 mm, RADIOPAQUE
32008R   SIZE 8 mm, RADIOPAQUE
32009R   SIZE 9 mm, RADIOPAQUE

 FEATURES:

  • Angled extraluminal limb.
  • Implant grade silicone.
  • Non-adherent smooth surface.
  • Safety ring and groove system.
  • Available in clear or radiopaque material.
 
YUKARI GERİ DÖN
 
resmi büyütün
+sipariş ver
 
 
Ürün adı: 4200 SERIES STANDARD
Ürün kodu: 4200
Özellikleri:

The 4200 Series Standard Safe-T-Tube™ is the original design featuring dimensions that will work for the majority of surgical cases.  Shortened limbs can be ordered directly from our facility at no additional charge.  Available in sizes 10mm, 11mm, 12mm, 13mm, 14mm, 15mm, and 16mm (outside diameter) in either clear or radiopaque implant grade silicone.  Each Safe-T-Tube™ set includes the tube, two plug/ring sets, and product information.  15mm adaptors and additional plug/ring sets are available.  Refer to chart below for corresponding product codes.

INDICATIONS FOR USE:

Acute laryngotracheal injuries.
To support intrathoracic tracheal stenosis.
To support a reconstructed trachea.
Tracheal stenosis.
To support a reconstituted trachea.
Segmental resection and anastomosis.
To maintain a cervical trachea that cannot be repaired.

SUPPLIED:

Sterile, 1 tube per carton

PRODUCT CODES:

420010    SIZE 10 mm, CLEAR
420011   SIZE 11 mm, CLEAR
420012   SIZE 12 mm, CLEAR
420013   SIZE 13 mm, CLEAR
420014   SIZE 14 mm, CLEAR
420015   SIZE 15 mm, CLEAR
420016   SIZE 16 mm, CLEAR
     
42010R     SIZE 10 mm, RADIOPAQUE
42011R   SIZE 11 mm, RADIOPAQUE
42012R   SIZE 12 mm, RADIOPAQUE
42013R   SIZE 13 mm, RADIOPAQUE
42014R   SIZE 14 mm, RADIOPAQUE
42015R   SIZE 15 mm, RADIOPAQUE
42016R   SIZE 16 mm, RADIOPAQUE

 FEATURES:

  • Original design.
  • Implant grade silicone.
  • Non-adherent smooth surface.
  • Safety ring and groove system.
  • Available in clear or radiopaque material.
 
YUKARI GERİ DÖN
 
resmi büyütün
+sipariş ver
 
 
Ürün adı: 4500 SERIES HEBELER
Ürün kodu: 4500
Özellikleri:

The 4500 Series Hebeler Safe-T-Tube™ features an integral internal balloon to adjust the airflow through the upper end of the tube.  The balloon can be inflated for intermittent closure of the upper limb, creating a closed system between the tracheotomy and lungs.  Following anesthesia or ventilation, the balloon is deflated and the upper limb becomes open for upper respiratory access.  Available in sizes 12mm, 15mm, and 18mm (outside diameter) in clear medical grade silicone.  Each Safe-T-Tube™ set is supplied with the tube, two plug/ring sets, and product information.  15mm adaptors and additional plug/ring sets are available.  Refer to chart below for corresponding product codes.

INDICATIONS FOR USE:

Acute laryngotracheal injuries.
To support intrathoracic tracheal stenosis.
To support a reconstructed trachea.
Tracheal stenosis.
To support a reconstituted trachea.
Segmental resection and anastomosis.
To maintain a cervical trachea that cannot be repaired.

SUPPLIED:

Sterile, 1 tube per carton

PRODUCT CODES:

450012     SIZE 12 mm, CLEAR
450015   SIZE 15 mm, CLEAR
450018   SIZE 18 mm, CLEAR

 FEATURES:

  • Patented internal balloon design.
  • Implant grade silicone.
  • Non-adherent smooth surface.
  • Safety ring and groove system.
  • Available in clear material.
 
YUKARI GERİ DÖN
 
resmi büyütün
+sipariş ver
 
 
Ürün adı: 5200 SERIES THORACIC
Ürün kodu: 5200
Özellikleri:

The 5200 Series Thoracic Safe-T-Tube™ features an extra-long lower limb for thoracic applications.  Shortened limbs can be ordered directly from our facility at no additional charge.  Available in sizes 10mm, 11mm, 12mm, 13mm, 14mm, 15mm, and 16mm (outside diameter) in either clear or radiopaque implant grade silicone.  Each Safe-T-Tube™ set is supplied with the tube, two plug/ring sets, and product information.  15mm adaptors and additional plug/ring sets are available.  Refer to chart below for corresponding product codes.

INDICATIONS FOR USE:

Acute laryngotracheal injuries.
To support intrathoracic tracheal stenosis.
To support a reconstructed trachea.
Tracheal stenosis.
To support a reconstituted trachea.
Segmental resection and anastomosis.
To maintain a cervical trachea that cannot be repaired.

SUPPLIED:

Sterile, 1 tube per carton

PRODUCT CODES:

 

520010     SIZE 10 mm, CLEAR
520011   SIZE 11 mm, CLEAR
520012   SIZE 12 mm, CLEAR
520013   SIZE 13 mm, CLEAR
520014   SIZE 14 mm, CLEAR
520015   SIZE 15 mm, CLEAR
520016   SIZE 16 mm, CLEAR
     
52010R   SIZE 10 mm, RADIOPAQUE
52011R   SIZE 11 mm, RADIOPAQUE
52012R   SIZE 12 mm, RADIOPAQUE
52013R   SIZE 13 mm, RADIOPAQUE
52014R   SIZE 14 mm, RADIOPAQUE
52015R   SIZE 15 mm, RADIOPAQUE
52016R   SIZE 16 mm, RADIOPAQUE

 FEATURES:

  • Extra-long distal limb.
  • Implant grade silicone.
  • Non-adherent smooth surface.
  • Safety ring and groove system.
  • Available in clear or radiopaque material.
 
YUKARI GERİ DÖN
 
resmi büyütün
+sipariş ver
 
 
Ürün adı: 6200 SERIES EXTRA-LONG
Ürün kodu: 6200
Özellikleri:

The 6200 Series Extra-long Safe-T-Tube™ is designed to provide the surgeon the total freedom to customize the intraluminal limbs to any desired length.  Shortened limbs can be ordered directly from our facility at no additional charge.  Available in sizes 10mm, 11mm, 12mm, 13mm, 14mm, 15mm, and 16mm (outside diameter) in either clear or radiopaque implant grade silicone.  Each Safe-T-Tube™ set includes the tube, two plug/ring sets, and product information.  15mm adaptors and additional plug/ring sets are available.  Refer to chart below for corresponding product codes.

INDICATIONS FOR USE:

Acute laryngotracheal injuries.
To support intrathoracic tracheal stenosis.
To support a reconstructed trachea.
Tracheal stenosis.
To support a reconstituted trachea.
Segmental resection and anastomosis.
To maintain a cervical trachea that cannot be repaired.

SUPPLIED:

Sterile, 1 tube per carton

PRODUCT CODES:

620010     SIZE 10 mm, CLEAR
620011   SIZE 11 mm, CLEAR
620012   SIZE 12 mm, CLEAR
620013   SIZE 13 mm, CLEAR
620014   SIZE 14 mm, CLEAR
620015   SIZE 15 mm, CLEAR
620016   SIZE 16 mm, CLEAR
     
62010R   SIZE 10 mm, RADIOPAQUE
62011R   SIZE 11 mm, RADIOPAQUE
62012R   SIZE 12 mm, RADIOPAQUE
62013R   SIZE 13 mm, RADIOPAQUE
62014R   SIZE 14 mm, RADIOPAQUE
62015R   SIZE 15 mm, RADIOPAQUE
62016R   SIZE 16 mm, RADIOPAQUE

 FEATURES:

  • Extra-long upper and lower limbs.
  • Implant grade silicone.
  • Non-adherent smooth surface.
  • Safety ring and groove system.
  • Available in clear or radiopaque material.
 
YUKARI GERİ DÖN
 
resmi büyütün
+sipariş ver
 
 
Ürün adı: HEALY / MONTGOMERY® STENT 8200 SERIES HMS SYSTEM™
Ürün kodu: 8200
Özellikleri:

The 8200 Series HMS System™ is designed to provide support during repair and/or reconstruction procedures of the subglottis and trachea. The system combines the features of the original Montgomery® Safe-T-Tube™ with the advantages of an inner cannula system. Once the stent is in place, the inner cannula can be removed for cleaning without disturbing repaired areas. The inner cannula has a 15mm end to connect respiratory accessories. When repair is complete, the HMS System can be removed endoscopically. Available in sizes 7mm, 9mm, and 11mm (outside diameters). Each HMS System includes the outer tube, two inner cannulas, one plug (for upper internal limb), one exterior flange, one lubrication kit, one neck strap, and product information.

INDICATIONS FOR USE:

Acute laryngotracheal injuries.
To support a reconstructed trachea.
Treatment of laryngotracheal stenosis.
To support a reconstituted trachea.
Segmental resection and anastomosis.
To maintain a cervical trachea that cannot be repaired.

SUPPLIED:

Sterile, 1 HMS System™ per carton

PRODUCT CODES:

820007     SIZE 7 mm
820009   SIZE 9 mm
820011   SIZE 11 mm

 FEATURES:

  • Complete system with inner cannula.
  • Medical grade material
  • Non-adherent smooth surface.
  • Safety ring and groove system.
 
YUKARI GERİ DÖN
 
resmi büyütün
+sipariş ver
 
 
Ürün adı: 7200 SERIES TAPERED
Ürün kodu: 7200
Özellikleri:

The 7200 Series Tapered Safe-T-Tube™ is designed to assist with the management of tracheal, subglottic, and glottic stenoses.  The superior end conforms to the contour of the glottis and subglottis, while the larger inferior portion simultaneously acts as a stent for the trachea.  The tapered end is designed to project up beyond the true vocal cords to the level of the laryngeal ventricle.  Available in sizes 8mm/10mm and 10mm/13mm (outside diameters) in either clear or radiopaque implant grade silicone.  Each Safe-T-Tube™ set includes the tube, two plug/ring sets, and product information.  15mm adaptors and additional plug/ring sets are available.  Refer to chart below for corresponding product codes.

INDICATIONS FOR USE:

Acute laryngotracheal injuries.
To support intrathoracic tracheal stenosis.
To support a reconstructed trachea.
Tracheal stenosis.
To support a reconstituted trachea.
Segmental resection and anastomosis.
To maintain a cervical trachea that cannot be repaired.

SUPPLIED:

Sterile, 1 tube per carton

PRODUCT CODES: 

721008    SIZE 8 mm/10 mm, CLEAR
721310    SIZE 10 mm/13 mm, CLEAR
     
71008R     SIZE 8 mm/10 mm, RADIOPAQUE
71310R   SIZE 10 mm/13 mm, RADIOPAQUE

 FEATURES:

  • Angled extraluminal limb
  • Implant grade silicone
  • Non-adherent smooth surface.
  • Safety ring and groove system.
  • Available in clear or radiopaque material.
 
YUKARI GERİ DÖN
 

ENGİN MEDİKAL LTD.ŞTİ.
MERKEZ:
Bornova Cad. No:7/25 İzeltaş Galeria Işıkkent - İZMİR/TÜRKİYE
TLF: 0232 472 06 55 - FAX: 0232 472 06 62

ŞUBE: 1420 sok. No:96/402 Alsancak - İZMİR/TÜRKİYE
TLF: 0232 463 85 14 - FAX: 0232 422 71 98
Designed by ALGORİTMA