KULAK - BURUN - BOĞAZ ÜRÜNLERİ
| |
|
|
|
|
| Ürün adı: |
3200 SERIES PEDIATRIC |
| Ürün kodu: |
3200 |
| Özellikleri: |
The 3200 Series Pediatric Safe-T-Tubes™ feature an angled extraluminal limb to facilitate suctioning and airway management. Shortened limbs can be ordered directly from our facility at no additional charge. Available in sizes 6mm, 7mm, 8mm, and 9mm (outside diameter) in either clear or radiopaque medical grade silicone. Each Safe-T-Tube™ set includes the tube, two plug/ring sets, and product information. Additional plug/ring sets are available. Refer to chart below for corresponding product codes.
INDICATIONS FOR USE:
Acute laryngotracheal injuries.
To support intrathoracic tracheal stenosis.
To support a reconstructed trachea.
Tracheal stenosis.
To support a reconstituted trachea.
Segmental resection and anastomosis.
SUPPLIED:
Sterile, 1 tube per carton
PRODUCT CODES:
| 320006 |
|
SIZE 6 mm, CLEAR |
| 320007 |
|
SIZE 7 mm, CLEAR |
| 320008 |
|
SIZE 8 mm, CLEAR |
| 320009 |
|
SIZE 9 mm, CLEAR |
| |
|
|
| 32006R |
|
SIZE 6 mm, RADIOPAQUE |
| 32007R |
|
SIZE 7 mm, RADIOPAQUE |
| 32008R |
|
SIZE 8 mm, RADIOPAQUE |
| 32009R |
|
SIZE 9 mm, RADIOPAQUE |
FEATURES:
- Angled extraluminal limb.
- Implant grade silicone.
- Non-adherent smooth surface.
- Safety ring and groove system.
- Available in clear or radiopaque material.
|
|
|
| YUKARI GERİ DÖN |
 |
| |
|
|
|
|
| Ürün adı: |
4200 SERIES STANDARD |
| Ürün kodu: |
4200 |
| Özellikleri: |
The 4200 Series Standard Safe-T-Tube™ is the original design featuring dimensions that will work for the majority of surgical cases. Shortened limbs can be ordered directly from our facility at no additional charge. Available in sizes 10mm, 11mm, 12mm, 13mm, 14mm, 15mm, and 16mm (outside diameter) in either clear or radiopaque implant grade silicone. Each Safe-T-Tube™ set includes the tube, two plug/ring sets, and product information. 15mm adaptors and additional plug/ring sets are available. Refer to chart below for corresponding product codes.
INDICATIONS FOR USE:
Acute laryngotracheal injuries.
To support intrathoracic tracheal stenosis.
To support a reconstructed trachea.
Tracheal stenosis.
To support a reconstituted trachea.
Segmental resection and anastomosis.
To maintain a cervical trachea that cannot be repaired.
SUPPLIED:
Sterile, 1 tube per carton
PRODUCT CODES:
| 420010 |
|
SIZE 10 mm, CLEAR |
| 420011 |
|
SIZE 11 mm, CLEAR |
| 420012 |
|
SIZE 12 mm, CLEAR |
| 420013 |
|
SIZE 13 mm, CLEAR |
| 420014 |
|
SIZE 14 mm, CLEAR |
| 420015 |
|
SIZE 15 mm, CLEAR |
| 420016 |
|
SIZE 16 mm, CLEAR |
| |
|
|
| 42010R |
|
SIZE 10 mm, RADIOPAQUE |
| 42011R |
|
SIZE 11 mm, RADIOPAQUE |
| 42012R |
|
SIZE 12 mm, RADIOPAQUE |
| 42013R |
|
SIZE 13 mm, RADIOPAQUE |
| 42014R |
|
SIZE 14 mm, RADIOPAQUE |
| 42015R |
|
SIZE 15 mm, RADIOPAQUE |
| 42016R |
|
SIZE 16 mm, RADIOPAQUE |
FEATURES:
- Original design.
- Implant grade silicone.
- Non-adherent smooth surface.
- Safety ring and groove system.
- Available in clear or radiopaque material.
|
|
|
| YUKARI GERİ DÖN |
 |
| |
|
|
|
|
| Ürün adı: |
4500 SERIES HEBELER |
| Ürün kodu: |
4500 |
| Özellikleri: |
The 4500 Series Hebeler Safe-T-Tube™ features an integral internal balloon to adjust the airflow through the upper end of the tube. The balloon can be inflated for intermittent closure of the upper limb, creating a closed system between the tracheotomy and lungs. Following anesthesia or ventilation, the balloon is deflated and the upper limb becomes open for upper respiratory access. Available in sizes 12mm, 15mm, and 18mm (outside diameter) in clear medical grade silicone. Each Safe-T-Tube™ set is supplied with the tube, two plug/ring sets, and product information. 15mm adaptors and additional plug/ring sets are available. Refer to chart below for corresponding product codes.
INDICATIONS FOR USE:
Acute laryngotracheal injuries.
To support intrathoracic tracheal stenosis.
To support a reconstructed trachea.
Tracheal stenosis.
To support a reconstituted trachea.
Segmental resection and anastomosis.
To maintain a cervical trachea that cannot be repaired.
SUPPLIED:
Sterile, 1 tube per carton
PRODUCT CODES:
| 450012 |
|
SIZE 12 mm, CLEAR |
| 450015 |
|
SIZE 15 mm, CLEAR |
| 450018 |
|
SIZE 18 mm, CLEAR |
FEATURES:
- Patented internal balloon design.
- Implant grade silicone.
- Non-adherent smooth surface.
- Safety ring and groove system.
- Available in clear material.
|
|
|
| YUKARI GERİ DÖN |
 |
| |
|
|
|
|
| Ürün adı: |
5200 SERIES THORACIC |
| Ürün kodu: |
5200 |
| Özellikleri: |
The 5200 Series Thoracic Safe-T-Tube™ features an extra-long lower limb for thoracic applications. Shortened limbs can be ordered directly from our facility at no additional charge. Available in sizes 10mm, 11mm, 12mm, 13mm, 14mm, 15mm, and 16mm (outside diameter) in either clear or radiopaque implant grade silicone. Each Safe-T-Tube™ set is supplied with the tube, two plug/ring sets, and product information. 15mm adaptors and additional plug/ring sets are available. Refer to chart below for corresponding product codes.
INDICATIONS FOR USE:
Acute laryngotracheal injuries.
To support intrathoracic tracheal stenosis.
To support a reconstructed trachea.
Tracheal stenosis.
To support a reconstituted trachea.
Segmental resection and anastomosis.
To maintain a cervical trachea that cannot be repaired.
SUPPLIED:
Sterile, 1 tube per carton
PRODUCT CODES:
| 520010 |
|
SIZE 10 mm, CLEAR |
| 520011 |
|
SIZE 11 mm, CLEAR |
| 520012 |
|
SIZE 12 mm, CLEAR |
| 520013 |
|
SIZE 13 mm, CLEAR |
| 520014 |
|
SIZE 14 mm, CLEAR |
| 520015 |
|
SIZE 15 mm, CLEAR |
| 520016 |
|
SIZE 16 mm, CLEAR |
| |
|
|
| 52010R |
|
SIZE 10 mm, RADIOPAQUE |
| 52011R |
|
SIZE 11 mm, RADIOPAQUE |
| 52012R |
|
SIZE 12 mm, RADIOPAQUE |
| 52013R |
|
SIZE 13 mm, RADIOPAQUE |
| 52014R |
|
SIZE 14 mm, RADIOPAQUE |
| 52015R |
|
SIZE 15 mm, RADIOPAQUE |
| 52016R |
|
SIZE 16 mm, RADIOPAQUE |
FEATURES:
- Extra-long distal limb.
- Implant grade silicone.
- Non-adherent smooth surface.
- Safety ring and groove system.
- Available in clear or radiopaque material.
|
|
|
| YUKARI GERİ DÖN |
 |
| |
|
|
|
|
| Ürün adı: |
6200 SERIES EXTRA-LONG |
| Ürün kodu: |
6200 |
| Özellikleri: |
The 6200 Series Extra-long Safe-T-Tube™ is designed to provide the surgeon the total freedom to customize the intraluminal limbs to any desired length. Shortened limbs can be ordered directly from our facility at no additional charge. Available in sizes 10mm, 11mm, 12mm, 13mm, 14mm, 15mm, and 16mm (outside diameter) in either clear or radiopaque implant grade silicone. Each Safe-T-Tube™ set includes the tube, two plug/ring sets, and product information. 15mm adaptors and additional plug/ring sets are available. Refer to chart below for corresponding product codes.
INDICATIONS FOR USE:
Acute laryngotracheal injuries.
To support intrathoracic tracheal stenosis.
To support a reconstructed trachea.
Tracheal stenosis.
To support a reconstituted trachea.
Segmental resection and anastomosis.
To maintain a cervical trachea that cannot be repaired.
SUPPLIED:
Sterile, 1 tube per carton
PRODUCT CODES:
| 620010 |
|
SIZE 10 mm, CLEAR |
| 620011 |
|
SIZE 11 mm, CLEAR |
| 620012 |
|
SIZE 12 mm, CLEAR |
| 620013 |
|
SIZE 13 mm, CLEAR |
| 620014 |
|
SIZE 14 mm, CLEAR |
| 620015 |
|
SIZE 15 mm, CLEAR |
| 620016 |
|
SIZE 16 mm, CLEAR |
| |
|
|
| 62010R |
|
SIZE 10 mm, RADIOPAQUE |
| 62011R |
|
SIZE 11 mm, RADIOPAQUE |
| 62012R |
|
SIZE 12 mm, RADIOPAQUE |
| 62013R |
|
SIZE 13 mm, RADIOPAQUE |
| 62014R |
|
SIZE 14 mm, RADIOPAQUE |
| 62015R |
|
SIZE 15 mm, RADIOPAQUE |
| 62016R |
|
SIZE 16 mm, RADIOPAQUE |
FEATURES:
- Extra-long upper and lower limbs.
- Implant grade silicone.
- Non-adherent smooth surface.
- Safety ring and groove system.
- Available in clear or radiopaque material.
|
|
|
| YUKARI GERİ DÖN |
 |
| |
|
|
|
|
| Ürün adı: |
HEALY / MONTGOMERY® STENT 8200 SERIES HMS SYSTEM™ |
| Ürün kodu: |
8200 |
| Özellikleri: |
The 8200 Series HMS System™ is designed to provide support during repair and/or reconstruction procedures of the subglottis and trachea. The system combines the features of the original Montgomery® Safe-T-Tube™ with the advantages of an inner cannula system. Once the stent is in place, the inner cannula can be removed for cleaning without disturbing repaired areas. The inner cannula has a 15mm end to connect respiratory accessories. When repair is complete, the HMS System can be removed endoscopically. Available in sizes 7mm, 9mm, and 11mm (outside diameters). Each HMS System includes the outer tube, two inner cannulas, one plug (for upper internal limb), one exterior flange, one lubrication kit, one neck strap, and product information.
INDICATIONS FOR USE:
Acute laryngotracheal injuries.
To support a reconstructed trachea.
Treatment of laryngotracheal stenosis.
To support a reconstituted trachea.
Segmental resection and anastomosis.
To maintain a cervical trachea that cannot be repaired.
SUPPLIED:
Sterile, 1 HMS System™ per carton
PRODUCT CODES:
| 820007 |
|
SIZE 7 mm |
| 820009 |
|
SIZE 9 mm |
| 820011 |
|
SIZE 11 mm |
FEATURES:
- Complete system with inner cannula.
- Medical grade material
- Non-adherent smooth surface.
- Safety ring and groove system.
|
|
|
| YUKARI GERİ DÖN |
 |
| |
|
|
|
|
| Ürün adı: |
7200 SERIES TAPERED |
| Ürün kodu: |
7200 |
| Özellikleri: |
The 7200 Series Tapered Safe-T-Tube™ is designed to assist with the management of tracheal, subglottic, and glottic stenoses. The superior end conforms to the contour of the glottis and subglottis, while the larger inferior portion simultaneously acts as a stent for the trachea. The tapered end is designed to project up beyond the true vocal cords to the level of the laryngeal ventricle. Available in sizes 8mm/10mm and 10mm/13mm (outside diameters) in either clear or radiopaque implant grade silicone. Each Safe-T-Tube™ set includes the tube, two plug/ring sets, and product information. 15mm adaptors and additional plug/ring sets are available. Refer to chart below for corresponding product codes.
INDICATIONS FOR USE:
Acute laryngotracheal injuries.
To support intrathoracic tracheal stenosis.
To support a reconstructed trachea.
Tracheal stenosis.
To support a reconstituted trachea.
Segmental resection and anastomosis.
To maintain a cervical trachea that cannot be repaired.
SUPPLIED:
Sterile, 1 tube per carton
PRODUCT CODES:
| 721008 |
|
SIZE 8 mm/10 mm, CLEAR |
| 721310 |
|
SIZE 10 mm/13 mm, CLEAR |
| |
|
|
| 71008R |
|
SIZE 8 mm/10 mm, RADIOPAQUE |
| 71310R |
|
SIZE 10 mm/13 mm, RADIOPAQUE |
FEATURES:
- Angled extraluminal limb
- Implant grade silicone
- Non-adherent smooth surface.
- Safety ring and groove system.
- Available in clear or radiopaque material.
|
|
|
| YUKARI GERİ DÖN |
 |
|
|
|