Katarakt Cerrahisi

 
Intraokuler Lensler
 
  C Flex (570C)
  ______________________  
 
  C-Flex Aspheric (970C)
______________________  
 
  Superflex(620H)
  ______________________  
 
  Superflex Aspheric (920H)
______________________  
 
  Sulcoflex Aspheric (653L)
  ______________________  
 
  Sulcoflex Toric (653T)
  ______________________  
 
  Sulcoflex Multifocal (653F)
  ______________________  
 
  T-Flex Aspheric (573T/623T)
______________________  
 
  M-Flex (630F)
______________________  
 
  M-Flex T (588F/638F)
______________________  
 
Viscoelastikler
 
  Rayvisc
  ______________________  
 
Kanüller
 
  Retrobulbar
  ______________________  
 
  Peribulbar
  ______________________  
 
  Antherior Chamber
  ______________________  
 
  Capsulotomy
  ______________________  
 
  Hydrodissection
  ______________________  
 
  Viscoelastic
  ______________________  
 
Bıçaklar
 
  Dereceli Bıçaklar
  ______________________  
 
  Crescent
  ______________________  
 
  MVR
  ______________________  
 
  Slit
  ______________________  
 
  R Slit
  ______________________  
 
Sütürler
 
  Monoflaman
  ______________________  
 
  Virgin Silk
  ______________________  
 
  Polypropylene
  ______________________  
 
  Polyester
  ______________________  
 
  PGA
  ______________________  
 
Eye Shield & Üçgen Sponge
 
  Eye Shield & Üçgen Sponge
  ______________________  
 

Vitrektomi Cerrahisi

 
Retinal Implantlar
 
  Mira
  ______________________  
 

Glokom Cerrahisi

 
Glokom Ürünleri
 
  Molteno
  ______________________  
 

Oculoplasti

 
Oculoplasti Orbital Implant
 
  M Sphere
  ______________________  
 

Keratoplasti

 
  Jedmed-Altomed
  ______________________  
 

Cerrahi Ürünler

 
  Cerrahi Ürünler
  ______________________  
 
 
 
 
 
C-Flex ( FDA Onaylı )
 

The Rayner C-flex IOL (570C)

Hydrophilic Acrylic Injectable IOL with
Amon-Apple Enhanced Square Edge

  • FDA Approved.
  • AVH Technology® for perfect centration and stability
  • Unique Amon-Apple Enhanced Square Edge for reduced PCO
  • Manufactured from Rayacryl® hydrophilic acrylic co-polymer for:
    – High biocompatibility
    – Low PCO
    – Optical purity – no vacuoles or glistenings
    – Low Silicone Oil adherence
    – Superb handling characteristics.
  • In many cases, C-flex can be used for sulcus-fixation if inadequate capsular support precludes in-the-bag fixation. However, there is the potential for iris-chaffing and pigment dispersion for all conventional sulcus-positioned IOLs and this needs to be balanced against the specific patient’s needs and the intra-operative situation.

Power Availability

  • +8.0D to +30.0D in 0.5D increments
  • +30.0D to +34.0D in 1.0D increments
  • +18.0D to +24.0D in 0.25D increments

For lower power IOLs, see Superflex® lens range.

Physical parameters

  • Optic Diameter: 5.75mm
  • Overall Length: 12.00mm
  • Estimated SRK A-Constant: 118.0
  • Theoretical ACD: 4.97

The Rayner Single Use Soft-Tipped Injector

  • Syringe-shaped plastic injector with round nozzle
  • Sub 3.0 mm incision size
  • Convenience
  • Safety

Presentation

The Rayner C-flex (570C) hydrophilic acrylic injectable IOL is supplied in 0.9% saline solution in a pouched blister pack, sterilised by moist heat and presented in a convenient, ready to use Lens Injection System Pack containing:

  • One C-flex injectable IOL
  • One Rayner Single Use Soft-Tipped Injector